File: AM3XMP001_E 02/2000/eVIII • 26
8
P (bar)
Q (l/min)
P (bar)
Q (l/min)
P (bar)
Q (l/min)
P (bar)
Imput signal (%)
P (bar)
P (bar)
Imput signal (%)
OVERALL DIMENSIONS
ORDERING CODE
Max. operating pressure 320 bar
Max. ow 30 l/min
Min. ow 2 l/min
Max. ambient temperature 50° C
Linearity See diagrams
Max. hysteresis <3% of nominal value
Repeatibility error (150 ÷ 680 mA) XP3... <3%
Max contamination level class 8 in accordance
with NAS 1638 with fi lter ß
10
³75
Fluid temperature -20°C÷75°C
Fluid viscosity 10÷500 mm
2
/s
Weight 0,8 Kg
Operating specifi cations are valid for fl uids with
33 mm
2
/s viscosity at 40°C, using Aron control units
Fixing screws UNI 593 M5x70
(min. 8.8 material screws are recommended)
Tightening torque 4 ÷ 5 Nm / 0.4 ÷ 0.5 Kgm
AM.3.XMP... AMPLIFIER VALVES
FOR
PROPORTIONAL CONTROL VALVES
PRESSURE - FLOW RATE 1
P
RESSURE - FLOW RATE 2
P
RESSURE - FLOW RATE 3
Modular valve type AM.3.XMP... used together with the pressure proportional pilot type
XP.3.. becomes a pressure control valve piloted by proportional command for rates up to
30 lt/min. The possibility of external drainage on A ensures its correct operation even with back
pressure on the discharge side. Other valves types should be ordered separately.
AM Modular valve
3 CETOP 3/NG6
XMP maximum proportional
pressure
2 Spring 2 bar (standard)
0 Standard dowels
(1,2 dia supply 0,5 dia damper)
* I = Internal drainage at T
E = External draining at A
** 00 =No variant
V1 =Viton
1 Serial No.
Support plane
specifi cations
PRESSURE - SIGNAL 1 (Q=15L/MIN)
P
RESSURE - SIGNAL 2 (Q=15L/MIN)
P
RESSURE - SIGNAL 3 (Q=15L/MIN)
Input signal (%)
AM.3.XMP...
XP.3... CH. VIII PA GE 18